Main 281-324-0908  |  9AM - 6PM M-F (CDT)

NEUTRIK 4 Pole XLR Receptacle P Series, Female

NC4FP-1

NEUTRIK 4 Pole XLR Receptacle P Series, Female

TECHNICAL DATA
Electrical

  • Number of contacts: 3 – 7 (except MP: 3-6)
  • Rated voltage: 50 V ac
  • Contact resistance: < 5 m
  • Insulation resistance – initial: > 2 G
    • – after damp heat test: > 1 G
    • -IEC 68-2-30)
  • Dielectric strength: 1500 V dc
  • Rated current:
  • 3 pole: 16 I [A], 2.5/14 mm2/AWG, ≤ 4 C
  • 4 pole: 10 I [A], 1.5/16 mm2/AWG, ≤ 7 C
  • 5 and 6 pole: 7.5 I [A], 1.0/18 mm2/AWG, ≤ 7 C
  • 7 pole: 5 I [A], 1.0/18 mm2/AWG, ≤ 9 C

I … Rated current per contact
C … Capacitance between contacts

Mechanical

  • Lifetime: > 1000 mating cycles
  • Insertion / withdrawal force: ≤ 20 N
    • Retention method (Female versions only): – standard: latch lock
  • “-0” version: retention spring
  • Separating force: ≤ 20 N

Materials

  • Shell: ZnAl4Cu1, gal Ni or black Cr plating
  • Insert: PA 6.6 30% GR (glass reinforced)
  • Contacts: – female (3 pole): CuSn6
    • female (4-7pole) & male: CuZn39Pb3
  • Contact surface: gal 2 µm Ag or gal 0.2 µm Au hard alloy over 2 µm Ni
  • Latch lock & spring: CK 67 steel, treated

Environmental

  • Temperature range: -30° C to + 80° C
  • Flammability: UL 94HB
  • Solderability: complies with IEC 68-2-20

Compatibility:
Switchcraft® DxM, DxF Cannon XLRx31, XLRx32, dimensionally with D series

SKU# NC4FP-1

Go to Top